MICROCONTROLLERS with their inherent advantages are being increasingly used in the industry. With growing shortage and escalating cost of Electrical Energy, accurate monitoring of Air Conditioning parameters has become necessary.6A/C CONTROLLER is most useful for controlling A/Cs. This instrument is able to maintain Room Temperature with an accuracy of 0.1° C by automatic measurement of Room temperature and accordingly controlling A/C ON/OFF. It also protects Costly Air conditioner from ‘Unhealthy conditions’ such as over load/under load etc. by automatically cutting off the supply.


  • Input Voltage : 3 Phase 415 V, 50Hz (R, Y, B, N) to MCB.
  • Supply Voltage : 230 V AC, 50 Hz ± 15% separate for each A/C.
  • Contact Rating : 7A at 230 V AC for Compressor Live Outputs to Contactor coil & 10 A at 250 V AC for Alarm Potential Free Outputs(C, N/O).
  • Temperature Sensor : 40Amp single pole contactor for each A/C (230VAC) for ALARM contact.
  • Temperature Sensing Range : 0.0°C to 55.0 °C
  • Resolution: 1V for Voltage, 0.1 A for Current & 0.1°C for temperature.
  • Indications :
    1] Supply ON for A/C1 & A/C2, A/C3, A/C4, A/C5, A/C6. Colour: Green
    2] Underload / Overload Fault: Colour: Red
    3] Sensor Fail fault Colour: Red
    4] Room High fault Colour: Red
    5] Fire alarm Colour: Red
    6] Healthy Colour: Green
    7] Keys: 4 key keypad for settings.
    1] SET Key: To enter into FUNCTION SET Mode/To view the next set pt.
    2] Up Arrow Key: To increment the set point
    3] Down Arrow Key: To decrement the set point.
    4] ENTER Key: To come out of FUNCTION SET mode/To enter into menu/To accept the password
  • Mounting: Wall mounting
  • Sensing :
    1. Inbuilt current sensing for compressor.
    2. Temperature Sensing by precise Temp. Sensor.
    3. Fire Alarm sensing.
  • Terminals:
    1. Separate O/P s for each Compressor.
    2. Temperature sensor.
    3. Alarm relay o/p.
  • Alarms/ Protections:
    1. Over load protection set point user settable.
    2. Under load protection set point user settable.
    3. High/low temperature alarm set point user settable.
  • RUN MODE PARAMETERS :
    1. Room Temperature
    2. CP1, CP2 CP3 CP4 CP5 CP6 Amp.
    3. Fault message if any
  • FAULTS/PROTECTION :
    1. Primary Fault related to protections of, A/C1, A/C2, A/C3, A/C4, A/C5, A/C6 Under load (UL) & Room Low.
    2. Secondary Fault related to protections of, A/C1, A/C2, A/C3, A/C4, A/C5, A/C6:- Overload (OL).
    3. Room Temperature High
    4. Room sensor fail / Room High protection.
    5. Fire Alarm Protection.
    6. MCB is used for Short circuit protection.
  • Fully programmable.
  • Complete protection for A/C from unhealthy condition.
  • All set points programmable from keypad.
  • Password protection for controller.
  • Four key interface for on site programming.
  • Separate alarm contacts for A/C fail alarm.
  • Automatic display of A/C parameters one by one in Run Mode.
  • Status, Healthy & Alarm indication by LED on front panel.
  • Room temperature sensing by precise sensor.
  • Direct display of actual current drawn by each compressor.
  • Direct display of actual room temperature.
  • Sequencing of comp. for equal run hours, site selectable.
  • Automatic Timer mode operation if Room sensor fails.
  • All Faults are Auto resettable.